ORIGINAL ARTICLE
Resource-aware colorectal computational pathology using public haematoxylin-eosin datasets: uncertainty, calibration, stability, dataset bias and controlled resolution analyses
Fucai Xie 1,2
,
 
,
 
,
 
,
 
,
 
 
 
 
More details
Hide details
1
Jiangxi University of Software Professional Technology, Nanchang, China
 
2
Shinawatra University, Pathum Thani, Thailand
 
3
Guangdong ATV College of Performing Arts, Zhaoqing, China
 
4
East China University of Political Science and Law, Shanghai, China
 
5
Jiangxi University of Chinese Medicine, Nanchang, China
 
6
Jinzhong College of Health, Jinzhong, China
 
7
Institute of Technology of Cambodia, Phnom Penh, Cambodia
 
 
Submission date: 2026-07-04
 
 
Final revision date: 2026-08-30
 
 
Acceptance date: 2026-10-14
 
 
Online publication date: 2026-11-27
 
 
Corresponding author
Fucai Xie   

Fucai Xie Jiangxi University of Software Professional Technology/No. 89 Luoting Avenue, Xinjian District Nanchang 330041 Jiangxi, China
 
 
 
KEYWORDS
TOPICS
ABSTRACT
Digital pathology increasingly connects routine haematoxylin-eosin (HE) morphology with quantitative image analysis, but pathology-facing artificial intelligence (AI) studies often report accuracy without uncertainty, calibration, stability or computational cost boundaries. We evaluated a resource-aware workflow for colorectal cancer (CRC) tissue classification using PathMNIST, a public benchmark derived from NCT-CRC-HE-100K (National Center for Tumor Diseases – NCT) and CRC-VAL-HE-7K, plus a public native-resolution 224 × 224 NCT-CRC subset. PathMNIST contained 89,996 training, 10,004 validation and 7,180 test patches across nine tissue classes. We compared transparent colour-texture baselines with a compact convolutional neural network (TinyCNN), reporting discrimination, paired patch-level bootstrap confidence intervals, calibration, repeated-seed stability and standardised compute cost. On the CRC-VAL-derived MedMNIST test split, TinyCNN achieved 0.848 accuracy (95% CI: 0.841–0.856) and 0.794 macro-F1 using 94,857 parameters, against 0.907 for the official ResNet-18 baseline, which uses approximately 118 times more parameters. Across six seeds, accuracy was 0.860 ±0.007, but macro one-vs.-rest area under the receiver operating characteristic curve range was 0.950–0.979 and its advantage over the random forest was not reproducible across seeds. In a controlled experiment in which only input resolution changed, accuracy fell monotonically from 0.953 at 224 pixels to 0.861 at 28 pixels. Critically, colour-histogram descriptors alone reached 0.767 accuracy and greyscale conversion reduced TinyCNN to 0.188, indicating that performance on this dataset family is substantially colour-driven rather than morphology-driven. The 224 × 224 analysis used an image-level validation subset from the same source family, not an independent patient-level test. These findings are retrospective public benchmark evidence, not clinical deployment validation.
REFERENCES (27)
1.
Li Y, Li T. Hardware and quality-control factors influencing digital pathology reproducibility. Pol J Pathol 2025; 76: 275-283.
 
2.
Bera K, Schalper KA, Rimm DL, Velcheti V, Madabhushi A. Artificial intelligence in digital pathology – new tools for diagnosis and precision oncology. Nat Rev Clin Oncol 2019; 16: 703-715.
 
3.
Song AH, Jaume G, Williamson DFK, Lu MY, Vaidya A, Miller TR, et al. Artificial intelligence for digital and computational pathology. Nat Rev Bioeng 2023; 1: 930-949.
 
4.
Miller M, Przybylska M, Pakuło S, Świderska-Chadaj Ż. The role of computational pathology in predicting expression of selected immunohistochemical markers. Pol J Pathol 2026; 77: 209-215.
 
5.
Korski K. Generation of virtual stains: can artificial intelligence imitate chemistry? Pol J Pathol 2026; 77: 203-208.
 
6.
Campanella G, Hanna MG, Geneslaw L, Miraflor A, Werneck Krauss Silva V, Busam KJ, et al. Clinical-grade computational pathology using weakly supervised deep learning on whole slide images. Nat Med 2019; 25: 1301-1309.
 
7.
Janowczyk A, Madabhushi A. Deep learning for digital pathology image analysis: a comprehensive tutorial with selected use cases. J Pathol Inform 2016; 7: 29.
 
8.
Kather JN, Krisam J, Charoentong P, Luedde T, Herpel E, Weis CA, et al. Predicting survival from colorectal cancer histology slides using deep learning: a retrospective multicenter study. PLoS Med 2019; 16: e1002730.
 
9.
Kather JN, Weis CA, Bianconi F, Melchers SM, Schad LR, Gaiser T, et al. Multi-class texture analysis in colorectal cancer histology. Sci Rep 2016; 6: 27988.
 
10.
Kather JN, Halama N, Marx A. 100,000 histological images of human colorectal cancer and healthy tissue (v0.1). Zenodo 2018. Available from: https://doi.org/10.5281/zenodo....
 
11.
Halder A, Dalal A, Gharami S, Woźniak M, Ijaz MF, Singh PK. A fuzzy rank-based deep ensemble methodology for multi-class skin cancer classification. Sci Rep 2025; 15: 6268.
 
12.
Ignatov A, Malivenko G. NCT-CRC-HE: not all histopathological datasets are equally useful. In: Lecture notes in computer science. Springer, Cham 2025, 300-317.
 
13.
Yang J, Shi R, Wei D, Liu Z, Zhao L, Ke B, et al. MedMNIST v2 – a large-scale lightweight benchmark for 2D and 3D biomedical image classification. Sci Data 2023; 10: 41.
 
14.
Dolezal JM, Srisuwananukorn A, Karpeyev D, Ramesh S, Kochanny S, Cody B, et al. Uncertainty-informed deep learning models enable high-confidence predictions for digital histopathology. Nat Commun. 2022; 13: 6572.
 
15.
Schwartz R, Dodge J, Smith NA, Etzioni O. Green AI. Commun ACM 2020; 63: 54-63.
 
16.
Lannelongue L, Grealey J, Inouye M. Green algorithms: quantifying the carbon footprint of computation. Adv Sci 2021; 8: 2100707.
 
17.
Goh KW, Surono S, Afiatin MYF, Mahmudah KR, Irsalinda N, Chaimanee M, et al. Comparison of activation functions in convolutional neural network for Poisson noisy image classification. Emerg Sci J 2024; 8: 592-602.
 
18.
Tejani AS, Klontzas ME, Gatti AA, Mongan JT, Moy L, Park SH, et al. Checklist for artificial intelligence in medical imaging (CLAIM): 2024 update. Radiol Artif Intell 2024; 6: e240300. doi: 10.1148/ryai.240300.
 
19.
Sounderajah V, Guni A, Liu X, Collins GS, Karthikesalingam A, Markar S, et al. The STARD-AI reporting guideline for diagnostic accuracy studies using artificial intelligence. Nat Med 2025; 31: 3283-3289.
 
20.
McGenity C, Bossuyt P, Treanor D. Reporting of artificial intelligence diagnostic accuracy studies in pathology abstracts: compliance with STARD for abstracts guidelines. J Pathol Inform 2022; 13: 100091.
 
21.
Mitchell M, Wu S, Zaldivar A, Barnes P, Vasserman L, Hutchinson B, et al. Model cards for model reporting. In: Proceedings of the Conference on Fairness, Accountability, and Transparency 2019, 220-229.
 
22.
Collins GS, Moons KGM, Dhiman P, Riley RD, Beam AL, van Calster B, et al. TRIPOD+AI statement: updated guidance for reporting clinical prediction models that use regression or machine learning methods. BMJ 2024; 385: e078378.
 
23.
Vasey B, Nagendran M, Campbell B, Clifton DA, Collins GS, Denaxas S, et al. Reporting guideline for the early-stage clinical evaluation of decision support systems driven by artificial intelligence: DECIDE-AI. Nat Med 2022; 28: 924-933.
 
24.
Macenko M, Niethammer M, Marron JS, Borland D, Woosley JT, Guan X, et al. A method for normalizing histology slides for quantitative analysis. 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro 2009, 1107-1110.
 
25.
Breiman L. Random forests. Mach Learn 2001; 45: 5-32.
 
26.
Pedregosa F, Varoquaux G, Gramfort A, Michel V, Thirion B, Grisel O, et al. Scikit-learn: machine learning in Python. J Mach Learn Res 2011; 12: 2825-2830.
 
27.
Paszke A, Gross S, Massa F, Lerer A, Bradbury J, Chanan G, et al. PyTorch: an imperative style, high-performance deep learning library. Adv Neural Inf Process Syst 2019; 32: 8024-8035.
 
eISSN:2084-9869
ISSN:1233-9687
Journals System - logo
Scroll to top